Prepare for the Cisco Designing Cisco Data Center Infrastructure exam with our extensive collection of questions and answers. These practice Q&A are updated according to the latest syllabus, providing you with the tools needed to review and test your knowledge.

QA4Exam focus on the latest syllabus and exam objectives, our practice Q&A are designed to help you identify key topics and solidify your understanding. By focusing on the core curriculum, These Questions & Answers helps you cover all the essential topics, ensuring you're well-prepared for every section of the exam. Each question comes with a detailed explanation, offering valuable insights and helping you to learn from your mistakes. Whether you're looking to assess your progress or dive deeper into complex topics, our updated Q&A will provide the support you need to confidently approach the Cisco 300-610 exam and achieve success.

The questions for 300-610 were last updated on Feb 18, 2025.
  • Viewing page 1 out of 41 pages.
  • Viewing questions 1-5 out of 204 questions
Get All 204 Questions & Answers
Question No. 1

An engineer configured the OSPF protocol in the vPC topology. During the catastrophic failure of one of the vPC the member switches, the traffic was routed to a black hole. This route was caused by the long convergence time caused by the delay of the of the vPC member switch reboot. After the failure, the engineer rebooted both switches, but the secondary switch powered on before the primary one. It caused all the vPCs to be shut down due to consistency-check violations. Which two features must be used to prevent these situations from happening in the future? (Choose two.)

Show Answer Hide Answer
Question No. 2

The end users report issues with datastore reachability between the newly installed virtual machines (VMs) and the storage array. The VMs are deployed on a Cisco C-Series server, directly connected with Cisco Nexus 5672UP switches over FCoE VLAN. The data traffic on VLAN 99, which is designated as a native VLAN, reaches its default gateway, but FCoE VLAN 99 fails to access the datastore. Which action resolves the problem?

Show Answer Hide Answer
Correct Answer: C

Question No. 3

Refer to the exhibit.

The Cisco Nexus Series Switch with hostname Nexus! is the default gateway for server A and server B Both servers must have reachability to the internet; however, server A internet traffic must pass through the firewall for deep packet inspection. Also, the firewall must inspect any communication between server A and server B. Which solution must be applied to separate the data plane path for server A and server B?

Show Answer Hide Answer
Correct Answer: B

Question No. 4

An engineer finishes the initial set up of a VXLAN EVPN network. The engineer is asked to plan for connectivity that supports redundancy and extends multiple virtual routing and forwarding domains. The requirement is to use the same default gateway addressing across all leaf switches that belong to the VXLAN network. Which two solution must be used to meet these requirements? (Choose two)

Show Answer Hide Answer
Question No. 5

A company has added a new FCoE storage array to increase the performance of datastore access for end users. This storage array is directly connected to the Cisco Nexus 5672UP switches using four 10G port-channel interfaces. After deployment, the end users fail to access the datastore compared to the older solution. A network engineer verified the port-channel interface and finds that the congestion occurs when PFC frames are generated at the FCoE ingress interface. Which action must be taken to resolve the congestion issue?

Show Answer Hide Answer
Correct Answer: B