Prepare for the Dell EMC Dell PowerEdge XE9680 and XE8640 Install exam with our extensive collection of questions and answers. These practice Q&A are updated according to the latest syllabus, providing you with the tools needed to review and test your knowledge.
QA4Exam focus on the latest syllabus and exam objectives, our practice Q&A are designed to help you identify key topics and solidify your understanding. By focusing on the core curriculum, These Questions & Answers helps you cover all the essential topics, ensuring you're well-prepared for every section of the exam. Each question comes with a detailed explanation, offering valuable insights and helping you to learn from your mistakes. Whether you're looking to assess your progress or dive deeper into complex topics, our updated Q&A will provide the support you need to confidently approach the Dell EMC D-PEXE-IN-A-00 exam and achieve success.
A deployment engineer is preparing to install three PowerEdge XE9680 servers in a rack supplied by the customer.
What must they before going on-site to install the servers?
Server Dimensions and Rack Compatibility:
The Dell PowerEdge XE9680 is a large server with specific dimensional requirements. Ensuring that the customer's rack can accommodate the physical length and depth of the server is crucial for a successful installation.
Rack Depth and Space Requirements:
Measure the depth of the customer's rack to ensure it is sufficient to house the XE9680 servers. The server's dimensions, including its length, should be verified against the available space in the rack.
Server Length Specification:
The PowerEdge XE9680 has a significant depth, typically around 800mm (31.5 inches). The rack must be deep enough to support the full length of the server, including any cable management and airflow requirements.
Checking Rack Specifications:
Verify that the rack adheres to standard dimensions suitable for hosting enterprise-grade servers. Ensure that the rack has appropriate mounting options, such as square or threaded holes compatible with the server's rail kit.
Pre-installation Verification:
Before arriving on-site, confirm with the customer that their rack meets the necessary specifications. This includes checking for sufficient clearance at the rear for cable connections and at the front for proper airflow.
Importance of Proper Fit:
A rack that cannot accommodate the length of the servers will result in installation failure, potential damage to the hardware, and inefficient cooling. It may also pose safety risks during and after installation.
Reference and Documentation:
The Dell EMC PowerEdge XE9680 Installation and Service Manual provides detailed information on the server's dimensions and the necessary rack specifications. This manual should be consulted to ensure all pre-installation requirements are met.
Dell EMC PowerEdge XE9680 Installation and Service Manual: This manual provides comprehensive guidelines on the server's physical dimensions and the necessary rack specifications for proper installation.
Dell EMC Technical Specifications Guide: Offers detailed specifications and requirements for rack compatibility and server installation procedures.
A deployment engineer is installing a PowerEdge XE8640 server. The server is on a lift, and they have aligned the server inner rails with the rail assemble that are secured in the rack. The engineer
can only push the server into the rack a short distance before it stops. Pushing forcefully causes the rack to slide back.
What action should the deployment engineer take?
Understanding Rail Locks:
The PowerEdge XE8640 server rails are equipped with a locking mechanism to secure the server during transport and installation. This prevents the server from moving unintentionally and ensures stability.
Identifying the Issue:
When the server stops after being pushed only a short distance into the rack, it is likely due to the rail lock engaging. This lock must be released to allow the server to slide fully into place.
Releasing the Rail Lock:
Locate the rail lock mechanism on the rails. This is typically a lever or button that, when pressed, releases the lock, allowing the server to slide further into the rack.
Detailed Steps:
Align the Server: Ensure that the server is properly aligned with the rails before proceeding. Misalignment can cause the server to get stuck or make it difficult to release the lock.
Press the Release Mechanism: With the server partially inserted, locate and press the release mechanism on both sides of the rails. This should disengage the locks.
Slide the Server: Once the locks are released, carefully push the server into the rack until it is fully seated. Ensure that the server is evenly aligned to avoid binding or getting stuck.
Avoiding Forceful Methods:
Avoid using excessive force to push the server into the rack as it can cause damage to the server, rails, or rack. Additionally, pushing forcefully without releasing the rail lock can lead to misalignment and potential hardware issues.
Safety and Assistance:
Ensure the lift is stable and properly aligned with the rack to prevent movement. If needed, have an assistant stabilize the lift while performing the installation steps.
Reference to Official Documentation:
Refer to the Dell EMC PowerEdge XE8640 Installation and Service Manual for specific instructions and diagrams illustrating the rail lock mechanism and proper installation procedures.
Dell EMC PowerEdge XE8640 Installation and Service Manual: This manual provides detailed guidelines on the proper use of rail kits and the mechanism for releasing rail locks during server installation.
Dell EMC Technical Specifications Guide: Offers comprehensive details on the hardware specifications and installation processes for Dell PowerEdge servers, including rail systems and locking mechanisms.
A deployment engineer is installing a PowerEdge XE8640 server in a rack with round holes. They cannot get the outer rail portion to fit flush with the rack frame.
What is the reason the outer rail is not flush with the frame?
Understanding Rail Types and Compatibility:
Dell PowerEdge servers, including the XE8640, come with rail kits designed for specific types of racks. The rail kits are tailored to fit racks with square holes or threaded holes, depending on the model and configuration.
Compatibility with Round-Hole Racks:
The PowerEdge XE8640 does not support installation in round-hole racks. The rail kits provided with the XE8640 are designed for 4-post racks with square holes or 4-post threaded racks. Attempting to install these rails in a round-hole rack will result in improper fitment and stability issues.
Common Installation Issues:
If the outer rail portion does not fit flush with the rack frame, it is often due to a compatibility issue with the rack type. Round-hole racks require specific rail kits that are different from those used for square or threaded hole racks.
Verifying Rack Type:
Before installation, verify the type of rack being used. Ensure that it matches the specifications outlined in the server's installation guide. Using the correct rack type ensures proper fitment and structural integrity.
Alternative Solutions:
If the current rack is a round-hole type, consider using a compatible rack with square or threaded holes for the XE8640. Alternatively, there might be adapters or conversion kits available that allow the use of standard rails in round-hole racks, although these are not typically recommended due to potential stability issues.
Reference and Documentation:
Refer to the Dell EMC PowerEdge XE8640 Installation and Service Manual for detailed information on rail and rack compatibility. This manual provides specifications for supported rack types and instructions for proper installation.
Dell EMC PowerEdge XE8640 Installation and Service Manual: This document provides comprehensive guidelines on the correct installation procedures and compatible rack types for the XE8640 server.
Dell EMC Technical Specifications Guide: Offers detailed specifications on the rack compatibility and rail options for Dell PowerEdge servers, ensuring proper installation and fitment.
A deployment engineer is installing eight PowerEdge XE9680 servers. Two servers will be installed in each of four racks. The data center managers must plan for the power needed to supply power to
the four racks.
What power consumption information can the deployment engineer give the data center manager?
The PowerEdge XE9680 server is equipped with power supply units (PSUs) that are essential for its operation. Here's the power consumption information that the deployment engineer can provide:
Total Power Requirement: With two servers per rack, each rack will have a total ofeight 2800-Watt PSUs. This information helps in calculating the total power draw for each rack.
Power Planning: The data center manager must plan for the power needed to supply power to the four racks, considering the power draw of the servers and any additional equipment that will be installed.
By providing this detailed power consumption information, the deployment engineer assists the data center manager in planning for the appropriate power infrastructure to support the PowerEdge XE9680 servers.
A deployment engineer goes on-site to install a mix of XE systems in a customer testing and development data center. The customer engineering group is stress testing the PowerEdge XE servers to
determine the best XE server for their software applications. As one of the first steps, they must ensure the correct server rails are on-site.
Which three options are a correct matching of rail type with server type?
To ensure the correct server rails are on-site for the installation of PowerEdge XE servers, it's essential to match the server model with the appropriate rail type. Based on the Dell Enterprise Systems Rail Sizing and Rack Compatibility Matrix, the following matches are correct:
XE9680 and B25: The XE9680 server is compatible with the B25 rail type, which is designed to support the size and weight of this particular server model1.
XE9640 and B25: Similarly, the XE9640 server can also utilize the B25 rail type for secure mounting in a rack1.
XE9680 and B28: Additionally, the XE9680 server is compatible with the B28 rail type, providing an alternative mounting solution1.
It's important to note that the rail types are specific to the server models and are designed to ensure a secure and stable installation in the customer's rack. The Dell Rail Sizing and Rack Compatibility Matrix provides detailed information on the compatibility of different server models with their respective rail types. This document should be consulted to verify the correct rail type for each server model before proceeding with the installation1.
Full Exam Access, Actual Exam Questions, Validated Answers, Anytime Anywhere, No Download Limits, No Practice Limits
Get All 14 Questions & Answers