QA4Exam focus on the latest syllabus and exam objectives, our practice Q&A are designed to help you identify key topics and solidify your understanding. By focusing on the core curriculum, These Questions & Answers helps you cover all the essential topics, ensuring you're well-prepared for every section of the exam. Each question comes with a detailed explanation, offering valuable insights and helping you to learn from your mistakes. Whether you're looking to assess your progress or dive deeper into complex topics, our updated Q&A will provide the support you need to confidently approach the Dell EMC D-XTR-DY-A-24 exam and achieve success.
During the installation of an XtremlO cluster, you configure the ESRS server using a FQDN for Connect Home. During the test, you discover that the XtremlO cluster fails to connect home. What is a possible cause for this issue?
You are connecting a VMware cluster to an XtremlO array. The host will be connected to the array using QLogic Fibre Channel HBAs. Based on best practices, what is the recommended value for the Execution Throttle?
When connecting a VMware cluster to an XtremIO array using QLogic Fibre Channel Host Bus Adapters (HBAs), the recommended value for the Execution Throttle is typically set to 4096. This setting controls the maximum number of outstanding I/O operations that can be sent to a Fibre Channel port.
Here's how to apply this setting:
Access HBA Settings: Log into the VMware host and access the settings for the QLogic Fibre Channel HBA.
Locate Execution Throttle: Find the parameter for the Execution Throttle within the HBA settings.
Set Value: Change the value of the Execution Throttle to 4096. This is the recommended setting to balance performance and resource utilization.
Save and Apply: Save the changes and apply them to the HBA. A reboot of the host may be required for the changes to take effect.
Verify Configuration: After the host is back online, verify that the new Execution Throttle setting is active and functioning as expected.
Monitor Performance: Monitor the performance of the host and the storage array to ensure that there are no adverse effects from the change.
It's important to note that while the value of 4096 is a common recommendation, the optimal setting may vary based on the specific environment and workload. Therefore, it's essential to refer to the latest Dell XtremIO documentation and possibly consult with Dell support for the most current and tailored advice.
A customer has a 80 TB database which will not benefit from compression and deduplication. The customer does not project any future growth. What is the minimum recommended XtremIO X1 offering that meets this requirement?
For a customer with an 80 TB database that will not benefit from compression and deduplication, and with no projected future growth, the minimum recommended XtremIO X1 offering would be the one that provides at least 80 TB of raw storage capacity.
Based on the options provided:
A . 20 TB 4 X-Brick model
B . 40 TB 4 X-Brick model
C . 10 TB 8 X-Brick model
D . 20 TB 6 X-Brick model
The most suitable option that meets the requirement of providing at least 80 TB of raw storage capacity would be B. 40 TB 4 X-Brick model. This is because each X-Brick in the XtremIO X1 system contributes to the total raw storage capacity, and with a 4 X-Brick model, each X-Brick would need to provide at least 20 TB to meet the 80 TB requirement. Since the 40 TB 4 X-Brick model offers 40 TB per X-Brick, it would exceed the required capacity, ensuring that the customer's needs are met without any shortfall.
A four X-Brick XtremlO X1 cluster was installed in a customer's data center. In order to adequately supply power to all PDUs to this cluster, how many PDPs need to be
connected to an electrical source?
The process for connecting PDPs involves:
Identifying Power Requirements: Determine the power requirements for each component of the XtremIO X1 cluster, including X-Bricks and InfiniBand switches.
Allocating PDPs: Allocate the necessary number of PDPs based on the power requirements identified.
Connecting to Electrical Source: Connect each PDP to the electrical source, ensuring that the power distribution is balanced and meets the cluster's needs.
Verifying Power Supply: After connecting, verify that all components are receiving adequate power for operation.
Ensuring Redundancy: Ensure that there is redundancy in the power supply to protect against failures.
You are creating a virtual disk for a VMware VM running on vSphere 6.5. The VM will reside on a datastore provisioned from an XtremIO volume. You want to ensure proper
performance and capacity usage.
How should the disk be presented to the guest?
For a VMware VM running on vSphere 6.5 that will reside on a datastore provisioned from an XtremIO volume, the disk should be presented to the guest as Thick Provisioned, Eager Zero (EZT). This is recommended for the best performance and efficient capacity usage.
In conclusion, for ensuring proper performance and capacity usage for a VM on vSphere 6.5 with an XtremIO volume, Thick Provisioned, Eager Zero is the recommended method of disk presentation.