Handsome Savings - Limited Time Offer 30% OFF - Ends In 0d 0h 0m 0s Coupon code: 30OFF
Welcome to QA4Exam
Logo

- Trusted Worldwide Questions & Answers

Dell EMC D-XTR-MN-A-24 Exam Actual Questions

The questions for D-XTR-MN-A-24 were last updated on Sep 16, 2024.
  • Viewing page 1 out of 11 pages.
  • Viewing questions 1-5 out of 55 questions
Unlock Access to All 55 Questions & Answers
Question No. 2

What must be submitted with an RPQ prior to a dispersed XtremlO cluster installation?

Show Answer Hide Answer
Correct Answer: A

When submitting a Request for Product Qualification (RPQ) prior to a dispersed XtremIO cluster installation, it is necessary to include a wiring diagram and an X-Brick component location diagram. The wiring diagram provides a detailed representation of the electrical connections between the components, while the X-Brick component location diagram shows the physical placement of the X-Brick components within the installation environment. These documents are essential for planning the installation to ensure that all components are correctly positioned and connected for optimal performance and serviceability1.

The process for preparing these documents typically involves:

Creating a detailed wiring diagram that outlines all the necessary connections between the X-Brick components and other infrastructure elements.

Developing an X-Brick component location diagram that illustrates where each component will be physically located in the data center.

Reviewing the diagrams to ensure they meet the technical requirements and specifications for a dispersed XtremIO cluster installation.

Submitting the diagrams along with the RPQ for approval before proceeding with the installation.

These steps are crucial for a successful installation and are outlined in the Official Dell XtremIO Maintenance Achievement document1.


Question No. 3

Which ports need to be open between the XMS and X1-SC1 to successfully operate Technician Advisor on an XtremIO X2?

Show Answer Hide Answer
Correct Answer: C

To successfully operate Technician Advisor on an XtremIO X2, TCP ports 80 and 443 need to be open between the XMS (XtremIO Management Server) and X1-SC1 (Storage Controller). These ports are used for HTTP and HTTPS communication, respectively, allowing for secure management and operation of the storage system.


Question No. 4

Into which directory must the XtremApp software be copied on the XMS?

Show Answer Hide Answer
Correct Answer: A

The XtremApp software must be copied into the /xtremapp directory on the XtremIO Management Server (XMS). This directory is specifically designated for the XtremApp software, ensuring that it is stored in the correct location for installation and execution1.

The process for copying the software typically involves:

Accessing the XMS via a secure shell (SSH) connection.

Navigating to the root directory.

Locating or creating the /xtremapp directory.

Using the appropriate command to copy the XtremApp software from its source location to the /xtremapp directory on the XMS.

It is important to follow the Official Dell XtremIO Maintenance Achievement document for the correct procedures and to ensure that the software is placed in the proper directory for successful installation and operation1.

=========================


Question No. 5

What is the minimum XtremlO software version required for expanding a Starter X-Brick cluster?

Show Answer Hide Answer
Correct Answer: C

The minimum XtremIO software version required for expanding a Starter X-Brick cluster is 4.0.4. This version includes the necessary features and improvements to support the expansion process, ensuring compatibility and optimal performance.


Product Image

Unlock All Questions for Dell EMC D-XTR-MN-A-24 Exam

Full Exam Access, Actual Exam Questions, Validated Answers, Anytime Anywhere, No Download Limits, No Practice Limits

Get All 55 Questions & Answers