Handsome Savings - Limited Time Offer 30% OFF - Ends In 0d 0h 0m 0s Coupon code: 50OFF
Welcome to QA4Exam
Logo

- Trusted Worldwide Questions & Answers

Huawei H13-611_V4.5 Exam Actual Questions

The questions for H13-611_V4.5 were last updated on Oct 3, 2024.
  • Viewing page 1 out of 107 pages.
  • Viewing questions 1-5 out of 536 questions
Unlock Access to All 536 Questions & Answers
Question No. 1

Which statements are true about the SAN network? (Select All that Apply)

Show Answer Hide Answer
Correct Answer: B, C

The IP SAN can use the existing IP network, and it supports the iSCSI protocol. The FC SAN must be configured with dedicated iSCSI HBAs for servers, and the FC HBA used by the FC SAN cannot convert SCSI packets into FC packets.


Question No. 2

A bank purchases a new storage device. During the RAID level configuration, the bank requires that data reliability be improved and parity data be stored on different disks. Which RAID levels can meet the requirements? (Select All that Apply)

Show Answer Hide Answer
Correct Answer: B, D

RAID 5 and RAID 6 can meet the requirements as they both improve data reliability by storing parity data on different disks. RAID 0 and RAID 3 do not store parity data on different disks, so they would not meet the bank's requirements.


Question No. 3

Which statements are true about RAID 2.0+? (Select All that Apply)

Show Answer Hide Answer
Correct Answer: A, C

Question No. 4

Suppose, for cost control reasons, a startup company can acquire only one storage device to provide services. However, its services require high hardware reliability, so an engineer recommended a Huawei OceanStor all-flash storage system. Which statements describe the high reliability of the storage system? (Select All that Apply)

Show Answer Hide Answer
Correct Answer: A, B, D

The statements that describe the high reliability of the Huawei OceanStor all-flash storage system are A. It supports clusters consisting of multiple controller enclosures to improve the availability of the storage system, B. Interconnect I/O modules shorten failover time when a controller fails to provide better reliability, as compared with common I/O modules, and D. When a controller fails, l/Os of the faulty controller are redirected to another controller The host is unaware of the fault and services remain running properly. Statement C. Standard I/O modules shorten failover time when a controller fails to provide better reliability, as compared with interconnect I/O modules is false.


Question No. 5

Which statements are true about a dual-controller storage system? (Select All that Apply)

Show Answer Hide Answer
Correct Answer: A, D

In active-standby mode, only one controller works at a time and if one controller is faulty, services are not affected. In active-active mode, both controllers are active and the service failover is more efficient than in active-standby mode.


Product Image

Unlock All Questions for Huawei H13-611_V4.5 Exam

Full Exam Access, Actual Exam Questions, Validated Answers, Anytime Anywhere, No Download Limits, No Practice Limits

Get All 536 Questions & Answers