QA4Exam focus on the latest syllabus and exam objectives, our practice Q&A are designed to help you identify key topics and solidify your understanding. By focusing on the core curriculum, These Questions & Answers helps you cover all the essential topics, ensuring you're well-prepared for every section of the exam. Each question comes with a detailed explanation, offering valuable insights and helping you to learn from your mistakes. Whether you're looking to assess your progress or dive deeper into complex topics, our updated Q&A will provide the support you need to confidently approach the NFPA CFPE exam and achieve success.

The questions for CFPE were last updated on Mar 29, 2025.
  • Viewing page 1 out of 20 pages.
  • Viewing questions 1-5 out of 100 questions
Get All 100 Questions & Answers
Question No. 1

Which of the following would not require having to submit construction documents for all fire protection systems and the issuance of a permit by the AHJ?

Show Answer Hide Answer
Correct Answer: A

According to NFPA 1031, construction documents for all fire protection systems and permits issued by the Authority Having Jurisdiction (AHJ) are necessary for rehabilitation, installation, and modification processes. However, an acceptance test, which is the final inspection and verification conducted by the AHJ to ensure the system meets all operational criteria, does not require prior submission of documents for fire protection systems or issuance of a permit. This process is done after installation or modification is complete to confirm compliance with fire codes and standards. Thus, option A is the correct answer.

Top of Form

Bottom of Form


Question No. 2

Exhibit.

What is the occupancy classification of the conference rooms in the figure if they are used for meetings of less than 50 people?

Show Answer Hide Answer
Correct Answer: B

According to NFPA 101, Life Safety Code, conference rooms that are used for meetings with less than 50 people are typically classified under the 'Business' occupancy classification (NFPA 101, Chapter 6). This is because such small meetings are considered part of the normal operations of a business environment, and thus, the rooms are not considered 'Assembly' occupancy, which requires a larger number of people (usually 50 or more).


Question No. 3

What is the occupant load for a high school computer lab with an area of 682 ft2 (63 m2) net? Calculator

Show Answer Hide Answer
Correct Answer: B

For educational occupancies such as a high school computer lab, the occupant load factor is typically 35 square feet per person (NFPA 101, Life Safety Code, Table 7.3.1.2). The occupant load is calculated by dividing the total area by the occupant load factor: OccupantLoad=682ft235ft2/person19occupants\text{Occupant Load} = \frac{682 \, \text{ft}^2}{35 \, \text{ft}^2/\text{person}} \approx 19 \, \text{occupants}OccupantLoad=35ft2/person682ft219occupants


Question No. 4

A fire alarm component that only contains indicator lamps, alphanumeric displays, or other equivalent means in which each indication provides status information about a circuit, condition, or location is called

Show Answer Hide Answer
Correct Answer: A

An annunciator is a fire alarm component that provides visual indicators (such as lamps or alphanumeric displays) to show the status of various circuits, conditions, or locations in a fire alarm system. It helps responders quickly identify the location and nature of the alarm condition without needing to go to the control panel itself.


Question No. 5

What is the maximum distance a fire department access road can be located from the exterior door of a single family home with an approved automatic sprinkler system?

Show Answer Hide Answer
Correct Answer: C

According to NFPA 1, Fire Code, and NFPA 1141, Standard for Fire Protection Infrastructure for Land Development in Wildland, Rural, and Suburban Areas, the maximum distance a fire department access road can be from the exterior door of a single-family home equipped with an approved automatic sprinkler system is typically 150 feet (46 meters). This allows the fire department to access the property effectively while providing some flexibility in site planning and landscaping.