Question No. 1

Which of the following room adjacencies is most likely to require additional sound mitigating transmission measures if reprogramming is not possible?

Show Answer Hide Answer
Correct Answer: A

The adjacency of kitchens and nap rooms is particularly challenging due to the contrasting activities that occur in these spaces. Kitchens are areas of high activity, often generating significant noise from cooking and social interactions, while nap rooms require a quiet environment to facilitate rest and relaxation. Without the possibility of reprogramming these spaces to different locations, additional sound mitigation measures become essential to prevent noise transmission from the kitchen to the nap room. This scenario underscores the importance of thoughtful spatial planning and acoustic design in aligning with the WELL Building Standard's objective of creating environments that cater to the diverse needs of occupants, ensuring that spaces designated for rest and relaxation are adequately protected from disruptive noise.


Question No. 2

Please click on the Project Scenario B button to review the project scenario and answer the following question.

BAY TOWERS BY BAYLEAF - SEATTLE, UNITED STATES - PROJECT SCENARIO B. Bay Towers by Bayleaf is a 20-floor commercial building overlooking Elliot Bay in Seattle, United States.

The building enjoys abundant natural light through floor to ceiling windows which take in Elliot Bay city views. Although located behind a major highway (four-lanes of traffic), there is a pedestrian bridge which connects their ground floor reception to the riverfront park on the other side of the highway.

The building is owned and operated by Bayleaf Inc., a real-estate organization. The building is leased at a 70% occupancy rate by a range of tenants, including those in finance, technology and healthcare. The total expected occupancy of the building is 1,000 people.

Bay Towers is mechanically ventilated and currently has MERV 11 filters. As the building owner, Bayleaf provides HVAC fit-out for tenant spaces, but tenants complete the interior walls and supply the finishes and furniture themselves. While no food is provided by Bayleaf, some individual tenants do have pantries where they provide their own snacks and beverages for their own employees.

Bayleaf manages the building and operates the ground floor which includes the reception, building management office, meeting rooms, as well as the elevator banks on each floor and the rooftop. Meeting rooms are common amenities that are able to be booked by the tenants. Bayleaf has two employees that work at desks onsite, a receptionist at the front desk and a property manager in the building management office. PROJECT SCOPE & GOALS

Bayleaf has enrolled Bay Towers for WELL Core Certification to attract and retain high-quality tenants and address growing tenant demand for well-being facilities.

As part of the WELL Core Certification scope, Bayleaf intends to renovate their ground floor and are open to leveraging some of this space to include health and well-being programming.

The scope of renovation will also include upgrades to the base building, such as staircases, end-of-trip facilities and the air filtration system. The rooftop will also be converted into a public green space for tenants to use for recreation. Tables, chairs and barbeque facilities will be added, as well as several gardens, including edible plots and lawn areas.

Bayleaf is hoping their WELL Core Certification will provide some initial feature compliance for tenants wishing to also pursue WELL Certification for their spaces.

How many workstations need to be height-adjustable to satisfy the requirements of the preconditions?

Show Answer Hide Answer
Correct Answer: C

Focus on WELL Core:The question is specifically about WELL Core preconditions, which apply to the building owner/operator (Bayleaf), not individual tenants.

WELL v2 Precondition - V02 Part 1 (Ergonomic Workstation Design):Requires adjustable-height workstations for at least 25% of all workstations.

Calculation:Bayleaf manages the building and has 2 employees with desks - a receptionist and a property manager. 25% of 2 workstations is 0.5. Rounding up per WELL guidelines, at least 1 workstation should be height-adjustable. Since two people work within Bayleaf itself, both of their workstations need to be height-adjustable to meet the requirement.


WELL v2, Movement (V02: Ergonomic Workstation Design):Outlines the requirement for adjustable workstations for WELL preconditions.

Question No. 3

Which of the following describes the effects of insufficient illumination during the day and light exposure during the early night?

Show Answer Hide Answer
Correct Answer: B

Insufficient light during the day and excessive light exposure in the early night can lead to phase advances of the circadian rhythm. This means your body's internal clock shifts to an earlier schedule.expand_more


* WELL v2 Feature L03 Circadian Lighting Design (https://v2.wellcertified.com/wellv2/en/light/feature/3): This feature explains the impact of light on the circadian rhythm.

* General knowledge of circadian rhythms: Scientific research supports that insufficient light in the morning and too much light at night can shift a person's circadian rhythm forward (phase advance).

Question No. 4

A project's interior designer is designing a room that will act as a restorative space for future employees to break from work and relax. The space will be at least 75 ft2 (7 m2) plus 1 ft2 (0.1 m2) per regular occupant. It will also include features like dimmable lighting, sound masking and calming colors. What additional element(s) should the interior designer incorporate to contribute towards meeting the requirements of the respective WELL optimization?

Show Answer Hide Answer
Correct Answer: D

While other options could be beneficial, signage or educational materials directly support the core requirement of a restorative space by clearly communicating its purpose to users. This encourages the right mindset for relaxation and restoration.


* M07: Restorative Spaces (Part 1: Designated Space) This part of the feature outlines the need for clear purpose and communication of restorative areas. https://v2.wellcertified.com/wellv2/en/mind/feature/7

Question No. 5

At a local university, lecturers teaching in an auditorium receive feedback that students experience an echo during class.

The following is some basic information about the auditorium:

. There are a total of 200 fully upholstered seats (10 rows of 20 seats each)

. A fabric covered ceiling is installed, suspended 5 ft. (1.52 m) from the concrete slab above

. 50% of the floor is carpeted, with the other 50% bare concrete finish

. The walls are left as bare concrete

Which of the following design interventions would be most likely to reduce reverberation times in the auditorium?

Show Answer Hide Answer
Correct Answer: D

Among the choices listed, providing a fabric covering over the existing concrete walls would be the most effective design intervention to reduce reverberation times within the auditorium. Here's the breakdown:

The Problem:The feedback about echoes indicates that sound waves are persisting for too long within the space, creating overlapping sound reflections that interfere with clarity and comprehension.

Reverberation and Sound Absorption:Reverberation time is directly influenced by how much sound is absorbed or reflected by surfaces within a space. Hard, reflective materials like concrete prolong reverberation times.

Why Fabric Walls Are Most Effective:Adding fabric wall coverings introduces a significant amount of sound-absorbing material directly where it's most needed. This will drastically reduce sound reflections and shorten reverberation times, helping mitigate the echo problem.